Bruker

Bruker 500 MHz Dual Channel NMR Spectrometer with CP/MAS capability and Digital Avance 400 MHz Triple Channel NMR Spectrometer

500 MHz TWO CHANNEL NUCLEAR MAGNETIC RESONANCE (NMR) SPECTROMETER comprising:

(a) An ultra-shielded narrow bore (54mm) superconducting magnet, a stand with vibration damping facility  (  ̴4Hz) and a system for liquid helium with a hold time of at least  150 days

(b) A shim/lock system with lock control and lock receiver

(c) A frequency generator (6-600 MHz)

(c) A shim/lock system with lock control and lock receiver

(d) Transmitter/Receiver

(e) Preamplifier

(f) Appropriate workstation and software license

Contact Person/s

Name: Prof Joseph Philip Michael
Phone: +27 11-717-6753
Email: Joseph.Michael@wits.ac.za

Grantholder

Title: Prof
First Name: Joseph Philip
Last Name: Michael
Phone: +27 11-717-6753
Email: Joseph.Michael@wits.ac.za
Bruker 500 MHz Dual Channel NMR Spectrometer with CP/MAS capability and Digital Avance 400 MHz Triple Channel NMR Spectrometer

Bruker Microflex LT Matrix Assisted Laser Desorption Ionization-Time of Flight (MADLI-TOF) Mass Spectrometer (MS)

The Bruker Microflex LT MADLI-TOF system is an affordable, high-value benchtop MALD-TOF Mass Spetrometer with accurate mass determination for bio-molecules. The system includes a microSCOUT MALDI ion source with extended pulse ion extraction PANTM mass range focussing. The MALDI-TOF contains a 60Hz nitrogen laser used to ionise the sample. The Time of Flight analyser only allows only linear measurements, with no upgrade to TOF/TOF. The MALDI-TOF is accompanied by a Data System with a digitizer. The operating software om the central processing unit is Windows-XP.

Contact Person/s

Name: Prof Lise Korsten
Phone: +27 12-420-3295
Email: lise.korsten@up.ac.za

Grantholder

Title: Prof
First Name: Lisa
Last Name: Korsten
Phone: +27 12-420-3295
Email: Lise.korsten@up.ac.za
Bruker Microflex LT Matrix Assisted Laser Desorption Ionization-Time of Flight (MADLI-TOF) Mass Spectrometer (MS)

Bruker XRD Diffractometer X-ray Diffractometer (XRD)

The Nano and Non-Ambient XRD facility will require the following key components, a subsystem A-Optimised for XRR, GID, XRR and texture based components and  a subsystem B-optimised for PDF and high pressure in situ measurements.

Contact Person/s

Name: Professor David Billing
Phone: +27 11-717-6759
Email: dave.billing@wits.ac.za

Grantholder

Title: Prof
First Name: David
Last Name: Billing
Phone: +27 11-717-6959
Email: dave.billing@wits.ac.za
Bruker XRD Diffractometer  X-ray Diffractometer (XRD)

Bruker 80 V FTIR and Raman with Closed Cycle Helium Cryostat Fourier Transform Infrared Spectrometer (FTIR)

The Bruker 80 V FTIR/Raman system can perform spectroscopy measurements in the wavenumber range of 10 - 50,000 cm-1 (1,000 - 0.2 micrometer) with a resolution of 0.2 cm-1 . The instrument is fitted with a FTIR microscope, as well as a Raman microscope, allowing for micro-analysis of samples.

Contact Person/s

Name: Prof JAA Engelbrecht
Phone: +27 41-504-2186
Email: Japie.engelbrecht@nmmu.ac.za

Grantholder

Title: Prof
First Name: JAA
Last Name: Engelbrecht
Phone: +27 41-504-2186
Email: Japie.engelbrecht@nmmu.ac.za

Bruker 600 MHz Nuclear Magnetic Resonance (NMR) Spectrometer with Protein Capabilities Nuclear Magnetic Resonance Spectrometer (NMR)

The 600 MHz NMR spectrometer contains a 14.1 Tesla super-conducting shielded magnet, a 3-channel spectrometer with sample temperature control and two probes (both with z-gradients), viz., a triple resonance H, C, N probe (suitable for acquiring protein NMR data) and a broad band indirect observe probe (for routine small molecule NMR analysis).

Contact Person/s

Name: Dr P Kaye
Phone: +27 46-603-8254
Email: p.kaye@ru.ac.za

Grantholder

Title: Dr
First Name: P
Last Name: Kaye
Phone: +27 46-603-8254
Email: p.kaye@ru.ac.za
Bruker 600 MHz Nuclear Magnetic Resonance (NMR) Spectrometer with Protein Capabilities Nuclear Magnetic Resonance Spectrometer (NMR)

Bruker Bruker AVANCE IIITM 600MHz UltraShieldTM Plus Fourier Transform NMR Spectrometer

The High Performance Digital FT-NMR Spectrometer AVANCE IIITM 600 MHz is the ultimate NMR platform for life-science and materials research, and has a robust, automated, easy-to-use NMR analysis system for pharma/biotech, chemistry, 

Contact Person/s

Name: Test

Grantholder

Title: Prof
First Name: HCM
Last Name: Vosloo
Phone: +27 18-299-2358
Email: manie.vosloo@nwu.ac.za
Bruker Bruker AVANCE IIITM 600MHz UltraShieldTM Plus Fourier Transform NMR Spectrometer

Bruker D8 Advance Refractometer X-Ray Diffraction Spectrometer (XRDS) X-ray Diffractometer (XRD)

The XRD Spectrometer with micro-XRD, comprises of capillary spinning and high temperature attachments for structural analysis of a wide variety of materials, including nanomaterials and catalysts.

Contact Person/s

Name: Dr LM Cele
Phone: +27 12-382-6367
Email: celem@tut.ac.za

Grantholder

Title: Dr
First Name: LM
Last Name: Cele
Phone: +27 12-382-6367
Email: celem@tut.ac.za
Bruker D8 Advance Refractometer X-Ray Diffraction Spectrometer (XRDS) X-ray Diffractometer (XRD)

Bruker Explorer X-ray Fluoresence (XRF) Spectrometer

X-ray fluorescence analysis is one of the best analytical techniques to perform elemental analysis in all kind of samples, from liquids and solids to loose powders. X-Ray Fluorescence Spectrometry (XRF) is known for its unrivalled accuracy, precision and reliability. This robust analytical technology has made its way into all kinds of industrial applications, such as cement, polymers, refineries, mining, and industrial minerals. 

Contact Person/s

Name: Prof E van Steen
Phone: +27 21-650-2509
Email: evs@chemeng.uct.ac.za

Bruker X Band ESR Spectrometer Electron Spin Resonance spectrometer (ESR)

An electron spin resonance (ESR) is used to study chemical, biochemical, cellular and material samples (incl. nanomaterials) with unpaired electrons. The sensitivity of ESR spectroscopy is in the detection of low concentrations of radicals which makes the method ideal for monitoring the radical content of manufactured foods and beverages (beer/wine).

Contact Person/s

Name: Prof QQ Munro
Phone: +27 33-260-5270
Email: munroo@ukzn.ac.za

Grantholder

Title: Prof
First Name: QQ
Last Name: Munro
Phone: +27 33-260-5270
Email: munroo@ukzn.ac.za
Bruker X Band ESR Spectrometer Electron Spin Resonance spectrometer (ESR)

Bruker Total Protein/Peptide Solution (TP/PS) Total Protein/Peptide Solution

This instrument has a matrix-assisted laser desorption ionization (Maldi) time of flight (TOF) mass spectrometric (MS) analysis coupled with:

  • Ultra performance liquid chomatography (semi-prep HPLC)
  • Method development hardware and software
  • Various advanced detectors (diode array and evaporative light scattering detection)

Contact Person/s

Name: Dr T Govender
Phone: +27 31-260-8212
Email: govendertha@ukzn.ac.za

Grantholder

Title: Dr
First Name: T
Last Name: Govender
Phone: +27 31-260-8212
Email: govendertha@ukzn.ac.za